Removal of Radioactive Isotopes and Various Harmful Gases
ACU, Charcoal, Charcoal Filters.

Charcoal

  • Charcoal
  • Feature

    - ASTM D 3803
    - Test by Batch
    - Removal of radioactive gases
      and various harmful gases

  • Specifications
    Model Mesh

    Surface area(㎡/g)

    Base Carbon

    Grade

    Usage

    NT816 8 ⅹ16 1,000 ~ 1,200 Coconut Q

    Nuclear Power Plants

    NT230 20ⅹ30 1,000 ~ 1,200 Coconut Q

    Nuclear Power Plants

    NT450 40ⅹ50 1,000 ~ 1,200 Coconut Q

    Nuclear Power Plants

  • Physical Test
    Test Test Method Acceptance Value
    1.Apparent Density ASTM D2854 0.38 g/ml min.
    2.Particle Size Distribution ASTM D2862  
    - Retained on NO. 6 0.1% max.
    - Retained on NO. 8 5.0% max.
    - Through No. 8, Retained on NO. 12 60% max.
    - Through No.12, Retained on NO. 16 40% min.
    - Through No.16 5.0% max.
    - Through No.18 1.0% max.
    3.Ignition Temperature ASTM D3466 330℃ min.
    4.Carbon Tetrachloride Activity (on base) ASTM D3467 60.0% min.
    5.Ball-Pan Hardness ASTM D3802 92.0% min.
  • Radioactive Batch Test

    - A test performed on a representative sample of each batch of manufactured adsorbent

    - Methyl Iodide Removal

    - ASME AG-1 FF-5220
    - Test Method : ASTM D3803-89
    - Acceptance Value : 97.5% minimum (2 in Bed, 30℃, 95%RH)

  • Batch

    A quantity of adsorbent, not to exceed 10 m3 in size, of the same grade
    or type which has been produced under the same Manufacturer's
    production designation using a consistent manufacturing procedure and
    equipment, and which has been homogenized to exhibit the same physical
    properties and performance characteristics throughout its mass.